Data Centre Consulting + Tech Manpower hero image — CONSULTING infrastructure visual illustrating design, build and operate tier iii/iv data centres — globally, delivered by Xeon Broadband
23 · Consulting & Manpower · CONSULTING

Data Centre Consulting + Tech Manpower

Design, build and operate Tier III/IV data centres — globally.

End-to-end data centre advisory, design, commissioning and operations — plus certified DC engineers, critical-facility technicians and project managers deployed worldwide.

01 · OVERVIEW

What it is and who it's for

Xeon Broadband's Data Centre practice covers the full lifecycle of enterprise, colocation, hyperscale and edge facilities — from site selection, feasibility and Uptime Institute Tier III/IV design, through MEP/BMS commissioning (Levels 1–5), to 24×7 critical-facility operations and DCIM transformation.

We deploy certified manpower on demand: DC architects, electrical and mechanical engineers, BMS/EPMS specialists, fire & life safety engineers, white-space and structured-cabling technicians, DCIM administrators and CFM-certified facility managers — onsite anywhere in the world.

Vendor-neutral across Vertiv, Schneider, ABB, Caterpillar, Cummins, Stulz, Munters, Cisco, Juniper, Arista, and aligned with Uptime Institute, TIA-942, EN 50600, ASHRAE TC 9.9 and ISO 50001 frameworks.

Data Centre Consulting + Tech Manpower hero image — CONSULTING infrastructure visual illustrating design, build and operate tier iii/iv data centres — globally, delivered by Xeon Broadband — overview visual
AT A GLANCE
  • CategoryCONSULTING
  • GroupConsulting & Manpower
  • CoverageIndia + Global
  • DeliveryFully Managed
02 · CAPABILITIES

Core features

Site selection & feasibility

Power, fiber, water, climate, seismic and regulatory due diligence.

Tier III / IV design

Concurrently maintainable and fault-tolerant electrical, mechanical and network topologies.

Commissioning (Cx)

Levels 1–5 IST scripts, witnessing and as-built handover.

Critical facility operations

24×7 CFM, MOPs/SOPs/EOPs, change and incident management to Uptime M&O.

DCIM & sustainability

Asset, capacity, power and thermal management; PUE/WUE optimization and ISO 50001.

Migration & decommission

Workload moves, lift-and-shift, asset disposal and certified data destruction.

03 · HOW IT WORKS

Delivery architecture

  1. STEP 01

    Advise — site selection, capacity plan, TCO and target tier classification.

  2. STEP 02

    Design — electrical SLD, mechanical schematics, white-space layout, BMS/EPMS and network fabric.

  3. STEP 03

    Build — owner's engineer, vendor management, QA/QC and commissioning across all five levels.

  4. STEP 04

    Operate — 24×7 critical-facility manpower, DCIM, energy management and Uptime M&O alignment.

  5. STEP 05

    Optimize — PUE/WUE cycles, capacity reclamation, retrofits and sustainability reporting.

04 · SPECIFICATIONS & SLA

Engineered to numbers

TIER FRAMEWORKS
Uptime Tier III/IV · TIA-942 · EN 50600
CERTIFIED BENCH
500+ DC engineers & CFM techs
CERTIFICATIONS
ATD · ATS · CDCP/CDCS/CDCE · CFM · OSHA
COMMISSIONING
Levels 1–5 IST
VENDORS
Vertiv · Schneider · ABB · Cat · Cummins · Stulz
REGIONS
IN · GCC · APAC · EMEA · Americas · Africa
05 · PRICING TIERS

Pick the tier that fits

TIER 01

DC Advisory

From $28,000
  • →Site & feasibility study
  • →Tier-aligned concept design
  • →TCO & capex model
  • →Exec readout
Popular
TIER 02

Engineer On-Demand

From $4,800 / engineer / month
  • →Cert. DC / MEP / BMS engineer
  • →Onsite global mobilization
  • →Backfill guarantee
  • →Monthly governance
TIER 03

Managed Operations

Custom
  • →24×7 CFM crew
  • →MOP/SOP/EOP library
  • →DCIM operations
  • →Quarterly Uptime M&O review

Indicative pricing. All tiers can be customised — contact us for a tailored quote and SLA.

06 · USE CASES

Where customers deploy it

Greenfield hyperscale build

Owner's engineer for a 30 MW campus from site selection through Tier IV commissioning.

Colocation expansion

Add modular halls and upgrade power trains without breaching concurrent maintainability.

Edge & micro-DC rollout

Design and deploy 50+ edge sites across metros for low-latency workloads.

PUE turnaround

Airflow, set-point and chiller optimization to drop PUE from 1.8 to 1.35.

07 · CASE STUDY

A GCC sovereign cloud operator

Cloud & Government
CHALLENGE

Two 20 MW Tier III halls slipping by 9 months, with commissioning gaps, no operations runbooks and no certified facility manpower for go-live.

SOLUTION

Xeon Broadband mobilized an owner's-engineer pod plus 38 critical-facility staff — closed Cx gaps, authored the full MOP/SOP/EOP library and ran 24×7 operations from day one.

Go-Live Recovery
On revised plan
Availability (Y1)
100.000%
PUE Achieved
1.38
Uptime M&O
Approved

Client identity anonymized to protect commercial confidentiality. Metrics reflect realised outcomes from the engagement.

08 · FAQ

Frequently asked

Do you take owner's-engineer responsibility?+
Yes — fully independent of the contractor, accountable to the asset owner for design integrity, Cx and handover.
Can you operate facilities we did not design?+
Yes — we onboard existing sites with a gap assessment, MOP/SOP uplift and a phased operations cutover.
Are your engineers OEM-certified?+
Yes — Vertiv, Schneider, ABB, Cat and Cummins certifications are maintained on our bench.
Do you support Uptime Institute certification?+
Yes — we prepare designs, constructed facilities and operations for Tier Certification of Design, Constructed Facility and M&O Stamp.

Ready to deploy Data Centre Consulting + Tech Manpower?

Our solutions engineers will design and price the right architecture for your sites, applications and SLA targets.